PRODUCTS
Find products quickly
-
Motor frequency conversion control
-
Motor soft starter series
-
Tbqd series electromagnetic voltage regulating compensation soft starting device
-
Gsdq water resistance soft starter series
-
SDQ series water resistance soft starter
-
GGQ series (high voltage AC motor) high voltage solid state soft starter
-
Dgq series (AC motor) low voltage solid state soft starter
-
Gdcq electromagnetic voltage regulation soft start series
-
GDKQ series high-voltage reactance starting cabinet
-
-
Power system complete equipment
-
Dydzb series low voltage compensation cabinet
-
DDB low voltage dynamic compensation cabinet
-
GWJ series reactive power compensation cabinet
-
GCK low voltage withdrawable switchgear series
-
GGD AC low voltage distribution cabinet series
-
Xl-21 low voltage power distribution box series
-
XGN high voltage switchgear series
-
Kyn28a-12 high voltage switchgear series
-
MNS low voltage draw out switchgear series
-
GZDW DC panel
-
VDK series vacuum circuit breaker
-
-
Compensation product series
Welcome to consult now
Telephone consultation:
Business address:
GDCQ electromagnetic voltage regulating soft start series
- Product Description
- Principles and characteristics
- Model definition and selection instructions
- Technical parameter
- One time plan
Overcome the current technical bottleneck of high-voltage resistance of power electronic devices, and successfully expand the low-voltage soft-starting technology to the field of high-voltage motor soft-starting, and provide users with a high-voltage motor with high cost performance, high control accuracy, high stability and high reliability. Soft start control equipment.
products are widely used in building materials, metallurgy, mining, petroleum, chemical, electric power, papermaking, water conservancy, municipal administration and other industries.
-
Connect the high-voltage winding of the voltage regulator to the stator winding of the motor in series, and connect the low-voltage winding to the anti-parallel thyristor. According to the principle of the transformer, the terminal voltage of the high-voltage winding Ub1=K×Ub2 (K is the transformation ratio of the transformer). Using computer control technology to continuously adjust the conduction angle of the low-voltage side thyristor according to the starting requirements and control the change of Ub2, the terminal voltage Ub1 of the high-voltage winding can be controlled.
Motor terminal voltage: Ud=Us-Ur-Ub1
Us is the power supply voltage, and Ur is the voltage drop of the internal resistance of the power supply.
When starting, QF is closed first, and KM is disconnected. By controlling the conduction angle of the thyristor, the voltage Ub1 at both ends of the voltage regulator is gradually reduced, so that the voltage Ud at the motor terminal is gradually increased, the motor torque is gradually increased, and the speed is gradually increased. Rise to make the motor start smoothly. After starting, close the KM and put the motor into full-voltage operation.
By controlling the terminal voltage of the motor, the starting current is actually controlled. When the starting current is 2~3 times the rated current (about 1.5 when necessary), it is much lower than the full voltage starting current (5~7 times the rated current). Rated current). As a result, the voltage drop of the power grid during starting is greatly reduced, and the impact on electrical and mechanical equipment is also greatly reduced.
-
Please declare separately when ordering with special needs, and it will be adjusted according to user requirements.
When it is estimated that the current will be more than 3.5 times the rated current, the order should indicate the heavy-duty type.
Description:
1. The control part of the integrated cabinet and the transformer are in one cabinet, including the controller, thyristor components, voltage regulating transformer and short-circuit switch;
2, the combination cabinet is composed of a control cabinet and a transformer cabinet, and the control cabinet contains a controller, thyristor components and a short-circuit switch;
3, the split transformer is placed separately outside the cabinet, the control cabinet contains the controller, thyristor components, and the short-circuit switch needs to be equipped with a switch cabinet;
4. The overall dimensions of the product should be added to the structural dimensions plus the thickness of the front and rear door panels totaling about 50mm, and the thickness of the two ends plus the partitions totaling about 30mm;
5. The corresponding number of isolation cabinets needs to be increased when one is used for multiple times;
6. According to different user requirements and configurations, product size and layout can be adjusted according to actual conditions.
7. When the load is heavy, the estimated starting current is greater than 3.5 times the rated current, please indicate the heavy-duty type when selecting the model.
Description:
1, the control part of the integrated cabinet and the auto-voltage regulator are in one cabinet, including the controller, thyristor components, auto-voltage regulator and bypass switch;
2, each phase auto-voltage regulator of the split cabinet is a one-sided cabinet, including the controller, thyristor components, and the short-circuit switch needs to be equipped with a switch cabinet;
3. The overall dimensions of the product should be added to the structural dimensions plus the thickness of the front and rear door panels totaling about 50mm, and the thickness of both ends plus the partitions totaling about 30mm;
4. The corresponding number of isolation cabinets needs to be increased when using one towing multiple times;
5. According to user requirements and configurations, product size and layout can be adjusted according to actual conditions.
-
Start-stop mode: soft start, straight start, soft stop, free stop;
◎Control mode: smart, voltage ramp, constant time, sudden jump;
◎Operation mode: this cabinet, external control, communication remote control;
◎Setting method: 1--LCD screen, 2--background communication;
◎Communication: RS485 interface: Modbus communication protocol (default);
◎Starting sudden jump: 50%~90%Ue, time 0.5~2 seconds (adjustable);
◎Initial voltage: 10%~80%Ue (adjustable);
◎Starting current multiple: 1Ie~4Ie (adjustable);
◎Start and soft stop time: 1~120S;
◎Continuous start interval: 5-15 minutes (if necessary, it can be less than 2 minutes);
◎Cooling method: natural cooling; ◎LCD display: parameters such as starting current, starting time and fault information;
◎Chinese interface (other languages can be selected by default);
◎Main circuit working pressure: 6kV~15kV;
◎Operating power supply: AC220V/50Hz 300VA;
◎Protection grade: IP32.
Use environmental conditions
1. Ambient temperature: -20℃ 45℃;
2, the relative humidity of the air does not exceed 90%;
3, the altitude is not more than 2000m; (special design can be used when exceeding)
4, the inclination of the ground is not more than 5°;
5. There is no fire, explosion hazard, chemical corrosion and severe vibration at the installation site
Note: If there are special conditions of use, please indicate when ordering.
-
Share
Copyright: Dayu Electric Technology Co., Ltd 京ICP证000000号 TEL:0712-2883450 Address: No. 2, Hangtian Avenue, Xiaogan, Hubei