PRODUCTS
Find products quickly
-
Motor frequency conversion control
-
Motor soft starter series
-
Tbqd series electromagnetic voltage regulating compensation soft starting device
-
Gsdq water resistance soft starter series
-
SDQ series water resistance soft starter
-
GGQ series (high voltage AC motor) high voltage solid state soft starter
-
Dgq series (AC motor) low voltage solid state soft starter
-
Gdcq electromagnetic voltage regulation soft start series
-
GDKQ series high-voltage reactance starting cabinet
-
-
Power system complete equipment
-
Dydzb series low voltage compensation cabinet
-
DDB low voltage dynamic compensation cabinet
-
GWJ series reactive power compensation cabinet
-
GCK low voltage withdrawable switchgear series
-
GGD AC low voltage distribution cabinet series
-
Xl-21 low voltage power distribution box series
-
XGN high voltage switchgear series
-
Kyn28a-12 high voltage switchgear series
-
MNS low voltage draw out switchgear series
-
GZDW DC panel
-
VDK series vacuum circuit breaker
-
-
Compensation product series
Welcome to consult now
Telephone consultation:
Business address:
GDKQ series high-voltage reactance starting cabinet
- Product Description
- Principles and characteristics
- Model definition and selection instructions
- One time plan
The current during full voltage starting of an AC motor is approximately 6.5-7.5 times the rated current. The reactor starting cabinet can be used for step-down starting of AC motors with a rated voltage of 10kV and below, and a motor power of 4000KW and below. Its characteristic is that the starting current is generally 4-5 times the rated current, suitable for situations with relatively large network system capacity and lax starting current limits.
-
Selecting a reactor as a voltage reduction and current limiting device, when the motor starts, it is connected in series to the primary circuit. Due to the impedance of the reactance, a partial voltage drop is generated, causing a decrease in the terminal voltage of the motor, resulting in a decrease in the starting current compared to the full voltage (approximately 4-5 times the rated current). After starting, use a bypass switch to short circuit both ends of the reactance and switch the motor to full voltage operation.
In order to solve the dispersion of starting parameters and ensure the success rate of starting, the reactor generally adopts a tapping method to provide three different sets of parameters for on-site adjustment. The starting time is usually tens of seconds to two minutes.
In general, it is equipped with a dry type reactor with a temperature resistance level of F (155 ℃).
Cabinet type adopts XGN (modified) or KYN28 (modified)
Protection level IP31
-
-